Products
Products
Home /

RFID Cards and Accessories

/

Modules

/Wiegand output to relay dry point

New Products

Wiegand output to relay dry point

>Size: 88X50X31mm (including installation hole 96.5X50X31mm)

>Voltage and current: 9~15V100mA

>Relay maximum load: AC250V10A, DC30V10A

  • Brand:

    S4A
  • Item NO.:

    Wiegand-Dry
Specifications

Wiegand output to relay dry point

Model No.: Wiegand-Dry


Wiegand switch module

Instructions for use

All-in-one access control machines, face recognition machines, and fingerprint machines sold on the market have built-in relays to control the door lock switch. Since the devices are installed outside the door, they are easy to be damaged and short-circuited to open the door, posing potential safety hazards. This device can be installed in a safe place inside the door to isolate the access control identification device and the electric lock, and use the Wiegand output of the access control identification device to control the unlocking to improve the security of access control.


Size

88X50X31mm (including installation hole 96.5X50X31mm)

Voltage and current

9~15V100mA

Relay maximum load

AC250V10A, DC30V10A

Relay delay

minimum 1 second, maximum 60 seconds

Wiegand interface format

WG26~WG80

Manual switch input

1 channel (DR/GND), which can be connected to the door open button or dry contact signal

Unlocking rules

any Wiegand signal is fine


Wiegand output to relay dry point

Wiegand output to relay dry point

Wiegand output to relay dry point

Wiegand output to relay dry point

Set relay action hold time

(When setting, the module needs to be powered on and disconnect the card reader and relay interface)

***Short DR and GND first and keep shorted during setup***

1. The module relay action hold time defaults to 0.5~1s

2. Short-circuit D0 and GND for about 2 seconds, wait until the relay acts, and add a 10.5-second delay

Example: The relay action needs to be kept for 3 seconds, short-circuit DO and GND for 5 seconds, and then disconnect after hearing the relay action for 5 times, the setting is automatically saved and takes effect

3. Short-circuit D1 and GND for about 3 seconds, and the relay will act--the default hold time will be restored after being pressed

4. After the setting is completed, disconnect DR and GND to make the converter enter the working state


Wiegand output to relay dry point


Package

Wiegand output to relay dry point

Download

S4A Datesheet_Wiegand Output To Relay Dry Point

Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related Products
S4A Duplicate card number filter module
Duplicate card number filter module

>Wiegand interface format:WG26~WG80>Voltage and current:5~24V30mA

Bluetooth card reader
Bluetooth Card Reader 125khz for Access Control System

> Card type: EM, MF, Card> Metal Case, anti-vandal> Waterproof conforms to IP66> One relay(Pulse mode, toggle mode)> APP supports Android 4.3 and IOS7.0 above> Compatible with all Bluetooth-enabled mobile phones (version: 4.0 above)

Biometric Fingerprint Door Lock
Smart Biometric Fingerprint Glass Door Lock Built-In Time Attendance

> Finger Capacity: 1000> User Capacity: 3000> Semiconductor sensor(Support: Fingerprint+RFID+Pincode)Support USB to download attendance record

automatic garage door opener
Automatic Garage Door Opener Swing Opening Heavy Duty Door Operator With 2pcs Microwave Sensor

S4A Automatic Flat door systems with Pull arm or Push arm, support 110V  or 220V with a brushed motor> Power supply: 110V or 220V> Opening time: 3~7s / 90°> Opening and holding time: 1-30s> Protection level: IP12D

Interlock Module
Interlock Access Control Relay Module for 2 Doors

> Dimensions: 69x60x15mm> Operating temp: 5A/24V> Material: High quality elements with superb design> Suitable for Door: Fail-safe electric locks with  signal output> Output Capability: Applied to double-door interlocking

Relay Module
Door Control Relays Modules

> Dimensions: 36x34x20mm> Material: High quality elements with superb design> Suitable for Door: Externally-connected electronic lock of access controller> Output Capability: Dry contact output> Max. overload: 10A/250VAC 10A/30VDC

Voltage Switch Module
DC12-28VDC to DC12V Voltage Switch Module for Magnetic Locks

> Dimensions: 40x27x12mm> Input: 12-28VDC (Blue)> Output: 12VDC/1A (Green)

Time Delay Module
Time Delay 0-30seconds Control Module for Access Control Systems

>Working Voltage: DC12V>Working Current: 40MA>Unlock Delay: 5-30 seconds

S4A Duplicate card number filter module
Duplicate card number filter module

>Wiegand interface format:WG26~WG80>Voltage and current:5~24V30mA

Bluetooth card reader
Bluetooth Card Reader 125khz for Access Control System

> Card type: EM, MF, Card> Metal Case, anti-vandal> Waterproof conforms to IP66> One relay(Pulse mode, toggle mode)> APP supports Android 4.3 and IOS7.0 above> Compatible with all Bluetooth-enabled mobile phones (version: 4.0 above)

Biometric Fingerprint Door Lock
Smart Biometric Fingerprint Glass Door Lock Built-In Time Attendance

> Finger Capacity: 1000> User Capacity: 3000> Semiconductor sensor(Support: Fingerprint+RFID+Pincode)Support USB to download attendance record

automatic garage door opener
Automatic Garage Door Opener Swing Opening Heavy Duty Door Operator With 2pcs Microwave Sensor

S4A Automatic Flat door systems with Pull arm or Push arm, support 110V  or 220V with a brushed motor> Power supply: 110V or 220V> Opening time: 3~7s / 90°> Opening and holding time: 1-30s> Protection level: IP12D

Interlock Module
Interlock Access Control Relay Module for 2 Doors

> Dimensions: 69x60x15mm> Operating temp: 5A/24V> Material: High quality elements with superb design> Suitable for Door: Fail-safe electric locks with  signal output> Output Capability: Applied to double-door interlocking

Relay Module
Door Control Relays Modules

> Dimensions: 36x34x20mm> Material: High quality elements with superb design> Suitable for Door: Externally-connected electronic lock of access controller> Output Capability: Dry contact output> Max. overload: 10A/250VAC 10A/30VDC

Voltage Switch Module
DC12-28VDC to DC12V Voltage Switch Module for Magnetic Locks

> Dimensions: 40x27x12mm> Input: 12-28VDC (Blue)> Output: 12VDC/1A (Green)

Time Delay Module
Time Delay 0-30seconds Control Module for Access Control Systems

>Working Voltage: DC12V>Working Current: 40MA>Unlock Delay: 5-30 seconds

Leave A Message
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact